Clogging susceptibility of a drip irrigation system designed for family farming

Authors

  • Fábio Ponciano de Deus Universidade Estadual de Campinas/UNICAMP - Faculdade de Engenharia Agrícola/FEAGRI - Av. Cândido Rondon, 501 - CEP 13083-875 - Campinas - SP
  • Rhuanito Soranz Ferrarezi University of Georgia/UGA - Department of Horticulture/DH - 1111 Miller Plant Science Building - Zip code 30602 - Athens/GA - Estados Unidos
  • Renan Primo Universidade Estadual de Campinas/UNICAMP - Faculdade de Engenharia Agrícola/FEAGRI - Av. Cândido Rondon, 501 - CEP 13083-875 - Campinas - SP
  • Guilherme Alonso Martins Universidade Estadual de Campinas/UNICAMP - Faculdade de Engenharia Agrícola/FEAGRI - Av. Cândido Rondon, 501 - CEP 13083-875 - Campinas - SP
  • Roberto Testezlaf Universidade Estadual de Campinas/UNICAMP - Faculdade de Engenharia Agrícola/FEAGRI - Av. Cândido Rondon, 501 - CEP 13083-875 - Campinas - SP

DOI:

https://doi.org/10.25186/cs.v10i1.784

Keywords:

Family farming, drip irrigation, clogging degree

Abstract

Family farming is an important part of the agribusiness, accounting for a significant part of food production system that supplies the Brazilian domestic market. Irrigation equipment manufacturers have developed alternative technologies for family farming, as the KIFNET™ drip irrigation system, which uses only gravity to pressurize the emitters. The aim of this study was to evaluate the temporal variability of the hydraulic characteristics of a drip irrigation system for family farming, installed in accordance with manufacturer’s guidelines for coffee plants, and infer emitter clogging susceptibility. The evaluation was performed in the initial phase of plant growth during the dry season. New emitters were hydraulically evaluated using tap water, with the determination of the characteristic curve for five pressure values. We also evaluated the clogging susceptibility of the equipment (clogging degree, CD) when installed in the field and using water with suspended solids. In the evaluation with tap water, new emitters showed a coefficient of variation of 2.16 %, Christiansen’s uniformity coefficient (CUC) of 98.01%, and distribution uniformity (DU) of 96.84%. In the field evaluation, with the system operating according to the manufacturer guidelines, the uniformity coefficients have reached lower values than the tests with tap water (CUC=90.30% and DU=85.79%), because of the equipment layout in the field – as the area had a slope of 10% – and by the emitters clogging (CD=6.79%) after 24 irrigation events. The system uniformity and the manufacturing quality were classified as good according to the ASABE standard for drip irrigation, with average clogging degree within the acceptable range for the assessment time, showing technical feasibility for application of this system in family farming if used properly and with preventive maintenance.

 

References

AMERICAN PUBLIC HEALTH ASSOCIATION (APHA). Standard methods for the examination of water and wastewater. Washington: APHA/AWWA/WPCF, 1995. 798p.

AMERICAN SOCIETY OF AGRICULTURAL ENGINEERS (ASAE). Design and installation of microirrigation systems (EP405.1). St. Joseph: ASAE, 1994. 4p.

ASSOCIAÇÃO BRASILEIRA DE NORMAS TÉCNICAS (ABNT). Emissores para sistemas de irrigação localizada: Avaliação das características operacionais (PNBR 12:02.08.21). São Paulo: ABNT, 1986. 7p.

BORSSOI, A. L. et al. Water application uniformity and fertigation in a dripping irrigation set. Engenharia Agrícola, Jaboticabal, v. 32, n. 4, p. 718-726, 2012.

BUCKS, D. A.; NAKAYAMA, F. S.; GILBERT, R. G. Trickle irrigation water quality and preventive maintenance. Agricultural and Water Management, Netherlands, v. 2, n. 2. p. 149-162, 1979.

CARARO, D. C. et al. Analysis of clogging in drip emitters during wastewater irrigation. Applied Engineering in Agriculture, St. Joseph, v. 22, n. 2, p. 251-257, 2006.

CUNHA, F. F. et al. Manejo de micro-irrigação baseado em avaliação do sistema na cultura do meloeiro. Revista Caatinga, Mossoró, v. 21, n. 3, p. 147-155, 2008.

GUILHOTO, J. J. M. et al. PIB da agricultura familiar: Brasil-Estados. Brasília: NEAD Estudos, 2007. 172p.

FEDOROFF, N.V. et al. Radically rethinking agriculture for the 21st century. Science, Washington, v. 327 n. 5967, p. 833-834, 2010.

FERRAREZI, R. S. et al. Desenvolvimento vegetativo de mudas de café irrigadas por sistema de gotejamento para agricultura familiar. Coffee Science, Lavras, 2014. No prelo.

NASCIMENTO, J. M. S. et al. Avaliação da uniformidade de aplicação de água em um sistema de gotejamento para pequenas propriedades. Ciência e Agrotecnologia, Lavras, v. 33, n. especial, p. 1728-1733, 2009.

NIU, W.; LIU, L.; CHEN, X. Influence of fine particle size and concentration on the clogging of labyrinth emitters. Irrigation Science, Netherlands, v. 31, n. 4, p. 545-555, 2013.

REIS, E. F. et al. Avaliação do desempenho de sistemas de irrigação por gotejamento. Engenharia na Agricultura, Viçosa, v. 13, n. 2, p. 74-81, 2005.

SANTOS, F. S. S. et al. Efeito de diferentes lâminas de irrigação na cultura do mamão. Engenharia Agrícola, Jaboticabal, v. 28, n. 4, p. 673-680, 2008.

SOUZA, L. O. C. et al. Avaliação de sistemas de irrigação por gotejamento, utilizados na cafeicultura. Revista Brasileira de Engenharia Agrícola e Ambiental, Campina Grande, v. 10, n. 3, p. 541-548, 2006.

SOUZA, R. O. R. M.; PÉREZ, G. F. E.; BOTREL, T. A. Irrigação localizada por gravidade com microtubos. Irriga, Botucatu, v. 11, n. 2, p. 266-279, 2006.

TESTEZLAF, R. Irrigação: Métodos, sistemas e aplicações. Campinas: UNICAMP, 2011. 204p.

Published

2015-02-13

How to Cite

DEUS, F. P. DE; FERRAREZI, R. S.; PRIMO, R.; MARTINS, G. A.; TESTEZLAF, R. Clogging susceptibility of a drip irrigation system designed for family farming. Coffee Science - ISSN 1984-3909, v. 10, n. 1, p. 102 - 112, 13 Feb. 2015.

Issue

Section

Articles